TKC - Tiên Phong về giá trị

Danh mục sản phẩm

Đặt hàng nhanh

Danh mục sản phẩm

POINTEK ULS200 Overview

Đánh giá trung bình

(5/5)

1 Đánh giá

  • Mã sản phẩm:

    Thương hiệu: Siemens

  • Danh mục:

    Pointek ULS200

  • Tình trạng:

    Còn hàng
  • Giá:Liên hệ

Pointek ULS200 là công tắc siêu âm không tiếp xúc với hai điểm chuyển đổi để phát hiện mức chất rắn, chất lỏng và bùn dạng khối lớn trong nhiều ngành công nghiệp khác nhau; lý tưởng cho vật liệu dính.

Số lượng:

+

Overview

The Pointek ULS200 is an ultrasonic non-contacting switch with two switch points for level detection of bulk solids, liquids and slurries in a wide variety of industries; ideal for sticky materials.

Benefits

  • 2 switch outputs for high-high, high, low, and low-low level alarms or pump up/pump down control
  • Integral temperature compensation
  • AC or DC power supply
  • Electronics provided with fail-safe function
  • Threaded and sanitary fitting clamp process connections
  • Polycarbonate enclosure, Type 6/NEMA 6/IP67
  • Easy, two-button programming

Application

The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m (16.4 ft) for liquids and slurries. Unlike invasive contacting devices, there is no material buildup on the sensor.

The level switch has a rugged design, combining the transducer and electronics in one durable device. It has no moving parts and is virtually maintenance-free.

The transducer, available in ETFE or PVDF copolymer, is inert to most chemicals. This means the device can be used in the chemical, petrochemical, water, and wastewater industries. A sanitary version of the ULS200, with an industry standard flange option, is easy to remove from the application for cleaning. It thus satisfies the prerequisites for use in the food, beverage, and pharmaceutical industries. The Pointek ULS200 delivers superior performance while reducing maintenance, downtime, and equipment replacement costs.

  • Key Applications: liquids, slurries, fluid materials, plugged chute detection, chemical industry

Design

Installation

The Pointek ULS200 should be mounted in an area that is within the temperature range specified and that is suitable to the enclosure rating and materials of construction. The cover should be accessible to allow programming, wiring and display viewing.

It is advisable to keep the Pointek ULS200 away from high voltage or current runs, contactors and SCR control drives.

Locate the Pointek ULS200 so that it has a clear sound path perpendicular to the material surface. The sound path should not intersect the fill path, rough walls, seams, rungs etc.

Mounting and Interconnection

The Pointek ULS200 is available in three thread types: 2" NPT, R 2" (BSPT), EN 10226 or PF2 and can be fitted with the optional 75 mm (3 inch) flange adapter for mating to 3" ASME, DN 65, PN 10, and JIS 10K 3B sized flanges.

Separate cables and conduit may be required to conform to standard instrumentation wiring or electrical codes.

Configuration

Pointek ULS200 mounting

Technical specifications

Pointek ULS200

 

Mode of operation

 

Measuring principle

Ultrasonic level switch

Measuring range

 

Measuring range in liquids

0.25 ... 5 m (0.8 ... 16.4 ft)

Measuring range in bulk solids

0.25 ... 3 m (0.8 ... 9.8 ft)

Output

 

AC Version (relay)

2 SPDT Form C contacts, rated 5 A at 250 V AC or 30 V DC, resistive load; rated 1 A at 48 V DC resistive load

DC Version (relay)

2 SPDT Form C contacts, rated 5 A at 30 V DC, resistive load; rated 1 A at 48 V DC resistive load

DC Version (transistor)

2 switches, rated max. 100 mA, 48 V DC

Accuracy

 

AC/DC version

 

  • Resolution

3 mm (0.1 inch)

  • Repeatability

0.25 % of measuring range

Rated operation conditions

 

Installation conditions

 

  • Location

Indoors/outdoors

  • Beam angle

12°

Ambient conditions

 

  • Ambient temperature

-40 ... +60 °C (-40 ... +140 °F)

  • Storage temperature

-40 ... +60 °C (-40 ... +140 °F)

  • If mounted in metal threads

-20 ... +60 °C (-5 ... +140 °F)

Medium conditions

 

  • Process pressure

0.5 bar (7.25 psi) max.

Design

 

Material

Polycarbonate with gasket

Weight

Approx. 1.5 kg (3.3 lb)

Transducer material

PVDF or ETFE copolymer

Threaded mounting

2" NPT [(Taper), ASME B1.20.1]
R 2" [(BSPT), EN 10226]
or G 2" [(BSPP), EN ISO 228-1]

  • Optional flange adapter

For 3" ASME, DN 65, PN 10, and JIS 10 K3B

Sanitary mounting

4" sanitary fitting clamp

Power supply

 

AC version

100 ... 230 V AC, ± 15 %, 50/60 Hz, max. 12 VA, 5 W

DC version

18 ... 30 V DC, 3 W

Displays and controls

 

Display

LCD, three digits, 9 mm (0.35 inch) high, for display of distance between sensor face and material, multi-segment graphic for operating state

Memory

EEPROM, non-volatile

Programming

2 keys

Electronics/enclosure

Connection: terminal block, max. 2.5 mm2 (14 AWG) solid/1.5 mm2 (16 AWG) stranded

Degree of protection

IP67/Type 6/NEMA 6

Cable inlet

2 x ½" NPT or 2 x PG 13.5

Certificates and approvals

CE, UKCA, CCSAUS, FM

Options

Pointek ULS200 optional flange adapter, dimensions in mm (inch)

Dimensional drawings

Pointek ULS200, dimensions in mm (inch)

Circuit diagrams

Pointek ULS200 connections

 
 

1 đánh giá POINTEK ULS200 Overview

5

Chọn đánh giá của bạn
Zalo Facebook

Liên Hệ