SITRANS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids.

Benefits

  • High resistance to mechanical forces
  • Strong vibration resistance to high bulk material loads
  • Rotatable enclosure for convenient wiring
  • Suitable for low density material: standard version, 20 g/l (1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3) and low density option min. 5 g/l (0.3 lb/ft3)
  • Customer desired extensions up to 20 000 mm (787 inch)
  • Optional detection of solids within liquid
  • Durable short fork option with 165 mm (6.5 inch) insertion length

Application

The standard LVS200 detects high, low, or demand levels of dry bulk solids in bins, silos, or hoppers. The liquid/solid interface version can also detect settled solids within liquids or solids within confined spaces such as feed pipes. It is designed to ignore liquids in order to detect the interface between a solid and a liquid.

A pipe extension version is available with either the standard or liquid/solid interface electronics and fork, separated by a customer supplied 1 inch pipe.

SITRANS LVS200 has an optional 4 to 20 mA output for monitoring buildup on the fork to determine when preventative maintenance should be performed in sticky applications.

The LVS200 has a compact design and can be top, side or angle mounted. The vibrating fork design ensures the tines are kept clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged.

A signal from the electronic circuit excites a crystal in the probe causing the fork to vibrate. If the fork is covered by material, the change in vibration is detected by the electronic circuitry which causes the relay to change state after a one second delay. When the fork is free from material pressure, full vibration resumes and the relay reverts to its normal condition.

  • Key Applications: dry bulk solids in bins, silos, hoppers or settled solids within liquids (interface version)

Technical specifications

SITRANS LVS200

 

Mode of operation

 

 

Measuring principle

Vibrating point level switch

Input

 

Measured variable

High, low, and demand

Measuring frequency

 

  • Standard

125 Hz

  • Liquid/solid interface and short fork version

350 Hz

Output

 

PNP

Open collector:
Permanent load max. 0.4 A,
short-circuit and overload protected
Turn-on voltage: max. 50 V (reverse protection)

2-wire without contact

Load current:

  • Min. 10 mA
  • Max. 500 mA permanent
  • Max. 2A < 200 ms
  • Max. 5A < 50 ms

Voltage drop on the electronic module: max. 7 V with closed electric circuit

Cut-off current with open electric circuit: max. 5 mA

Relays

 

  • Version with 1 relay

SPDT relay

  • Version with 2 relays

DPDT relay

Relay delay

  • From loss of vibration:
    approximately 1 second
  • From resumption of vibration:
    approximately 1 ... 2 seconds

Signal delay

  • Probe uncovered to covered: approximately 1 second
  • Probe covered to uncovered: approximately 1 ... 2 seconds

Relay fail-safe

High or low, switch selectable

Alarm output

  • Relay 8 A at 250 V AC, non-inductive
  • Relay 5 A at 30 V DC, non-inductive

mA output

8/16 mA or 4 ... 20 mA

  • Resolution

4 ... 20 mA ± 0.1 mA

Sensitivity

High or low, switch selectable

Rated operating conditions

 

Installation conditions

 

  • Location

Indoor/outdoor

Ambient conditions

 

  • Ambient temperature

‑40 ... +60 °C (‑40 ... +140 °F)

  • Storage temperature

‑40 ... +80 °C (‑40 ... +176 °F)

  • Installation category

III

  • Pollution degree

2

Medium conditions

 

  • Process temperature
  • All except CSA Class II, Group G:
    -40 ... +150 °C (-40 ... +302 °F)
  • CSA Class II, Group G: -40 ... +140 °C (-40 ... +284 °F),
    CSA temperature code T3B
  • Max. threaded bushing temperature

80 °C (176 °F)

  • Max. enclosure surface temperature (Category 2D)

90 °C (194 °F)

  • Max. extension surface temperature (Category 1D)

150 °C (302 °F)

  • Pressure (vessel)

Max. 30 bar g (435 psi g) European Pressure Directive 2014/68/EU: Category 1

  • Minimum material density
  • Standard version: approx. 20 g/l (1.2 lb/ft3)
  • Liquid/solid interface version:
    approx. 50 g/l (3 lb/ft3)
  • Optional low density version:
    approx. 5 g/l (0.3 lb/ft3)

Design

 

Material

 

  • Enclosure

Epoxy coated aluminum

Process connection

  • Thread 1½" NPT [(Taper),
    ANSI/ASME B1.20.1], R ½" [(BSPT), EN 10226], and flange options
  • Optional sliding bushing with 2" NPT [(Taper), ANSI/ASME B1.20.1] or BSP thread
  • Thread material: stainless steel 303 (1.4301)

Tine material

Stainless steel 316L (1.4404),
PTFE-coated tines are available upon special request

Degree of protection

IP65/Type 4/NEMA 4

Conduit entry

2 x M20 x 1.5 or 2 x ½" NPT (For FM and CSA approved versions only.)

Weight

  • Standard version, no extensions: approx. 2.0 kg (4.4 lb)
  • Solids/liquids version, no extensions: approx. 1.9 kg (4.2 lb)

Power supply

  • 19 ... 230 V AC, +10 %, 50 ... 60 Hz, 8 VA
  • 19 ... 55 V DC, +10 %, 1.5 W

Certificates and approvals

 

 

  • CSA/FM General Purpose
  • CE
  • CSA/FM Dust Ignition Proof
  • RCM
  • ATEX II 1/2 D
  • CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class I, Aex ia IIC, CSA Class I, Ex ia IIC, available only with power supply options 5 and 6
  • ATEX II 1G and 1/2 G Eex ia IIC; ATEX II 1D and 1/2 D, available only with power supply option 5

Dimensional drawings